Green financing for data centers: what the bank audits
The sustainability of your data center stopped being a labeling argument and became a figure that someone is going to audit. On October 27, 2026, two operators closed green financing on the…
What we learn operating data centers and AI agents in Mexico — we write it here.
The sustainability of your data center stopped being a labeling argument and became a figure that someone is going to audit. On October 27, 2026, two operators closed green financing on the…
The concentration of data centers in Mexico is being reconfigured. Querétaro was during 2015-2022 the almost only destination…
The raised floor is the most expensive and least reversible infrastructure decision in your data center. Once you…
Whether you distribute perforated tile or directional flow grille across your raised floor is what determines whether your…
Grounding in a data center is the least visible but most critical electrical system to prevent equipment damage…
The sustainability of your data center stopped being a labeling argument and became a figure that someone is…
If your provider quotes you 40 MW and you accept them, once your racks are full you will…
If you’re evaluating a new data center and the first question that comes up is whether there’s enough…
If you’re evaluating where to locate a data center, you’ve already compared electricity rates and latency. You’re missing…
Water, not power, is the bottleneck for data centers in Mexico toward 2026. Querétaro, Monterrey, Guadalajara and CDMX…
When a CRAC or CRAH unit fails, the usual reaction is to call the provider and wait. However,…
Office air conditioning in a server room is the #1 cause of silent electronic damage in SMBs. It…
Office air conditioning in a server room is the #1 cause of silent electronic damage in SMBs. It…
A 1\text{ MW} GPU cluster consumes between 3 and 5 times more energy per rack than a CPU…
A 1\text{ MW} GPU cluster consumes 3 to 5 times more power per rack than a CPU cluster,…
Why your website feels the same from Monterrey as from Madrid Every time a user in Guadalajara opens…
Enterprise data centers in Mexico are already testing LLMs for internal use cases: handbook retrieval, post-incident report generation,…
Megacable is one of the cable and TV operators with the largest regional coverage in Mexico, and since…
ODATA landed in Mexico in 2022 with its QR01 campus in Querétaro, followed by QR02 and QR03 —…
ODATA landed in Mexico in 2022 with its QR01 campus in Querétaro, followed by QR02 and QR03 —…
Equinix landed in Mexico with two active campuses: Querétaro and Monterrey. In Querétaro it operates as the main…
If your provider offers you a medium-voltage UPS with zero transfer time that also promises to monetize your…
Confusing a PDU with a UPS causes more avoidable outages than almost any other data center design error.…
Confusing a PDU with a UPS causes more preventable outages than almost any other data center design error.…
The calculation your GPU rack vendor didn’t run — and that can take you offline Your UPS is…
A SOC 2 Type II audit for your data center can run anywhere from 6 to 9 months…
In the planning of your data center, water almost always shows up at the end: when you have…
A 20 MW data center in Mexico generates 4 critical environmental permits before the first stone. The sum…
A 20 MW data center in Mexico generates 4 critical environmental permits before the first stone. The 4…
When your data center provider assures you that it has available capacity, you tend to assume you will…
If your data center in Mexico operates without a DCIM (Data Center Infrastructure Management), the conservative figure is…
If your data center in Mexico operates without a DCIM, you're leaving between 12% and 30% of energy…
What separates a serious audit from a site tour Auditing a data center provider in Mexico is not…
When a provider sells you “leaf-spine design with ToR”, they are selling you an architecture decision with a…
When you design the cable path in a data center, mixing the electrical service entrance (power cables that…
The transceiver is not the cable — and the difference decides your migration project When a client asks…
800G and 1.6T are the cabling speeds dominating the data center roadmap from 2026 to 2030. Two technology…
When the remote hands technician opens your ticket while you are on call, they need to know exactly…
A UPS in alarm at eleven at night, six racks in a room and nobody on site. This…
If your data center operates without its own guard: when a power supply fails, someone from the provider…
It’s 3:00 AM and your UPS is alarming. The technician arriving at nine comes from another city, knows…