Cooling for Data Centers: Schneider Electric, APC and Uniflair

History of Schneider Electric, APC and Uniflair

Schneider Electric acquired APC in 2007, a leader in UPS and cooling. APC, founded in 1981, revolutionized power protection. Uniflair, created in 1988, joined in 2010, bringing precision cooling. Together, they offer efficient solutions for data centers, from edge to hyperscale.

InRow Cooling Solutions

Application: InRow units cool server racks directly. Ideal for small to medium data centers. They minimize air mixing, increasing efficiency in high-density environments.

Capacity: From 5 kW to 70 kW. Chilled water or direct expansion options.

Refrigerant: Direct expansion models use R410A; chilled water, no refrigerant.

Dimensions: Width of 300 mm or 600 mm, 1000 mm depth, 2000 mm height (e.g., ACRC300).

Condenser: Air or water-cooled, optimized for efficiency.

Technical Specifications: Uniflair InRow Cooling ACRC300/ACRC600

Historical Note: The InRow SC (ACSC100) was popular for small data centers, now replaced.

*NOTE: The capacities in this publication are for general reference only. For specific technical specifications, please contact the Noxtel sales team.

Perimeter Cooling Solutions

Application: They cool entire data center rooms. Ideal for medium to large facilities, with flexible airflow for edge and enterprise.

Capacity: From 20 kW to 150 kW, for high-density environments.

Refrigerant: Direct expansion with R410A; chilled water without refrigerant.

Dimensions: Vary, e.g., Uniflair AM: 800 mm width, 800 mm depth, 1900 mm height.

Condenser: Air or water-cooled, with remote condensers.

Technical Specifications: Uniflair Room Cooling

Historical Note: The Uniflair LE series was iconic for its reliability, evolved to Uniflair AM.

*NOTE: The capacities in this publication are for general reference only. For specific technical specifications, please contact the Noxtel sales team.

Rack, Ceiling, Wall or Backpack Solutions

Application: Compact, for micro data centers or edge computing. Rack cools individual racks; ceiling/wall saves space in small rooms.

Capacity: From 3.5 kW to 20 kW, for localized needs.

Refrigerant: R410A in direct expansion; chilled water options.

Dimensions: Rack (e.g., ACRMD4KT-1): 5U high, 19” wide; ceiling/wall varies.

Condenser: Air-cooled split or integrated systems.

Technical Specifications: Uniflair Rack Mounted Cooling

Historical Note: Uniflair SP Ceiling Mounted Split was key for small IT rooms.

*NOTE: The capacities in this publication are for general reference only. For specific technical specifications, please contact the Noxtel sales team.

Comparison Charts

InRow Cooling Comparison

ModelApplicationCapacityRefrigerantDimensions (WxDxH)Condenser
ACRC300Small-Medium Data Centers5-40 kWChilled Water300x1000x2000mmWater
ACRC600Medium Data Centers10-70 kWChilled Water600x1000x2000mmWater
ACRC100Small Data Centers5-30 kWR410A300x1000x2000mmAir

Perimeter Cooling Comparison

ModelApplicationCapacityRefrigerantDimensions (WxDxH)Condenser
Uniflair AMMedium-Large Data Centers20-100 kWR410A/Chilled Water800x800x1900mmAir/Water
Uniflair LELarge Data Centers50-150 kWR410A/Chilled Water1200x900x2000mmAir/Water

Rack/Ceiling/Wall Comparison

ModelApplicationCapacityRefrigerantDimensions (WxDxH)Condenser
ACRMD4KT-1Micro Data Centers3.5 kWR410A19”x5UAir
Uniflair SPSmall IT Rooms5-20 kWR410AVariesAir

Schneider, APC, Uniflair Equivalency Table

BrandProduct LineFocusIconic ModelsCurrent Equivalent
Schneider ElectricUniflair Master RangeComprehensive CoolingUniflair LEUniflair AM
APCInRow CoolingRack CoolingInRow SC (ACSC100)ACRC300/ACRC600
UniflairRoom CoolingPerimeter/Edge CoolingUniflair SPUniflair AM/SP

Conclusion

Schneider Electric, APC and Uniflair offer specialized cooling for data centers. InRow is ideal for high-density racks, Perimeter for large rooms, and Rack/Ceiling/Wall for compact spaces. Choose based on capacity, space and efficiency. Consult the technical specifications for details.

This is only a general guide to help understand the portfolio; product lines are always changing so for the most recent information consult the official pages