Preventive and Corrective Maintenance: The Key to Avoiding Failures

Regular maintenance prevents unexpected failures, improves performance, and extends the lifespan of equipment.

Why is it important?

It ensures the continuous operation of critical systems. These centers store and process essential data for any business operations, and any interruption can have serious consequences.

It helps identify problems before they turn into major failures, minimizing downtime and reducing unexpected costs.

Maintenance is essential to ensure the reliability, security, and efficiency of your IT infrastructure.

micro-data-center-5-2 Servicios de Mantenimiento

Fewer interruptions. Higher performance. Guaranteed security.

Diseno-sin-titulo-18 Servicios de Mantenimiento

Maintenance for Precision Air Conditioners

Includes inspection of electrical, electronic, and mechanical systems such as the control panel, connections, protections, and sensors. The flow and temperature of the cooling system, motors, fans, and valves are checked. Additionally, both the interior and exterior of the units are cleaned, and voltages and configuration parameters are reviewed.


Diseno-sin-titulo-19 Servicios de Mantenimiento

UPS Maintenance

UPS maintenance includes inspection of wiring, batteries, switches, and general cleaning. Voltages, currents, fans, and meters are checked. Additionally, connectors and air filters are adjusted, system synchronization is verified, and a fault simulation is performed. If applicable, PDUs are inspected, with loads and connections adjusted accordingly.

Diseno-sin-titulo-20 Servicios de Mantenimiento

Emergency Generator Maintenance

Emergency generator maintenance includes checking oil, diesel, and antifreeze levels, as well as electrical connections and potential leaks. With the equipment running, voltages, frequency, and any liquid or gas leaks are inspected. Parameters are adjusted, and a load test is performed to ensure proper operation.

ue Servicios de Mantenimiento

Leak Tightness Testing

Ensures that the room housing the equipment is properly sealed, allowing a gas extinguisher to function effectively in case of fire. The energy audit, which includes the Blower Door Test, detects air leaks using a high-powered fan, ensuring the space maintains the concentration of the extinguishing agent for the required duration.

ue-1 Servicios de Mantenimiento

Annual Preventive Maintenance Policy

We offer annual preventive and corrective maintenance policies for power backup and cooling systems in data centers. These policies cover regular maintenance services for UPS equipment, air conditioning systems, and chilled water handling units, ensuring their proper operation.

Do it with us