Cooling for Data Centers: Schneider Electric, APC, and Uniflair
History of Schneider Electric, APC, and Uniflair
Schneider Electric acquired APC in 2007, a leader in UPS and cooling solutions. Founded in 1981, APC revolutionized power protection. Uniflair, established in 1988, joined in 2010, bringing precision cooling expertise. Together, they provide efficient solutions for data centers, from edge to hyperscale.
InRow Cooling Solutions
Application: InRow units cool server racks directly. Ideal for small to medium data centers. They minimize air mixing, increasing efficiency in high-density environments.
Capacity: From 5 kW to 70 kW. Options for chilled water or direct expansion.
Refrigerant: Direct expansion models use R410A; chilled water models contain no refrigerant.
Dimensions: Width of 300 mm or 600 mm, 1000 mm depth, 2000 mm height (e.g., ACRC300).
Condenser unit: Air- or water-cooled, optimized for efficiency.
Technical Specifications: Uniflair InRow Cooling ACRC300/ACRC600
Historical Note: The InRow SC (ACSC100) was popular for small data centers but has now been replaced.

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.
Perimeter Cooling Solutions
Application: They cool entire data center rooms. Ideal for medium to large facilities, offering flexible airflow for edge and enterprise environments.
Capacity: From 20 kW to 150 kW, designed for high-density environments.
Refrigerant: Direct expansion with R410A; chilled water without refrigerant.
Dimensions: Vary, e.g., Uniflair AM: 800 mm width, 800 mm depth, 1900 mm height.
Condenser unit: Air- or water-cooled, with remote condensers.
Technical Specifications: Uniflair Room Cooling
Historical Note: The Uniflair LE series was iconic for its reliability, later evolved into the Uniflair AM.

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.
Rack, Ceiling, Wall, or Backpack Solutions
ApplicationCompact solutions for micro data centers or edge computing. Rack units cool individual racks; ceiling and wall units save space in small rooms.
Capacity: From 3.5 kW to 20 kW, for localized cooling needs.
Refrigerant: R410A in direct expansion; chilled water options available.
Dimensions: Rack (e.g., ACRMD4KT-1): 5U height, 19” width; ceiling/wall dimensions vary.
Condenser unit: Split systems, air-cooled or integrated.
Technical Specifications: Uniflair Rack Mounted Cooling
Historical Note: The Uniflair SP Ceiling Mounted Split was key for small IT rooms.

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.
Comparison Tables
InRow Cooling Comparison
Model | Application | Capacity | Refrigerant | Dimensions (W x D x H) | Condenser unit |
---|---|---|---|---|---|
ACRC300 | Small to Medium Data Centers | 5-40 kW | Chilled Water | 300x1000x2000mm | Water |
ACRC600 | Medium Data Centers | 10-70 kW | Chilled Water | 600x1000x2000mm | Water |
ACRC100 | Small Data Centers | 5-30 kW | R410A | 300x1000x2000mm | Air |
Perimeter Cooling Comparison
Model | Application | Capacity | Refrigerant | Dimensions (W x D x H) | Condenser unit |
---|---|---|---|---|---|
Uniflair AM | Medium to Large Data Centers | 20-100 kW | R410A / Chilled Water | 800x800x1900mm | Air / Water |
Uniflair LE | Large Data Centers | 50-150 kW | R410A / Chilled Water | 1200x900x2000mm | Air / Water |
Rack/Ceiling/Wall Comparison
Model | Application | Capacity | Refrigerant | Dimensions (W x D x H) | Condenser unit |
---|---|---|---|---|---|
ACRMD4KT-1 | Micro Data Centers | 3.5 kW | R410A | 19”x5U | Air |
Uniflair SP | Small IT Rooms | 5-20 kW | R410A | Varies | Air |
Table of Equivalences Schneider, APC, Uniflair
Brand | Product Line | Focus | Iconic Models | Current Equivalent |
---|---|---|---|---|
Schneider Electric | Uniflair Master Range | Comprehensive Cooling | Uniflair LE | Uniflair AM |
APC | InRow Cooling | Rack Cooling | InRow SC (ACSC100) | ACRC300/ACRC600 |
Uniflair | Room Cooling | Perimeter/Edge Cooling | Uniflair SP | Uniflair AM/SP |
Conclusion
Schneider Electric, APC, and Uniflair offer specialized cooling for data centers. InRow is ideal for high-density racks, Perimeter units for large rooms, and Rack/Ceiling/Wall units for compact spaces. Choose based on capacity, space, and efficiency. Refer to technical specifications for details.
This is only a general guide to help understand the portfolio; product lines are always changing, so for the most up-to-date information, please consult the official websites.