Cooling for Data Centers: Schneider Electric, APC, and Uniflair

Enfriamiento para Data Centers: Schneider Electric, APC y Uniflair

History of Schneider Electric, APC, and Uniflair

Schneider Electric acquired APC in 2007, a leader in UPS and cooling solutions. Founded in 1981, APC revolutionized power protection. Uniflair, established in 1988, joined in 2010, bringing precision cooling expertise. Together, they provide efficient solutions for data centers, from edge to hyperscale.

InRow Cooling Solutions

Application: InRow units cool server racks directly. Ideal for small to medium data centers. They minimize air mixing, increasing efficiency in high-density environments.

Capacity: From 5 kW to 70 kW. Options for chilled water or direct expansion.

Refrigerant: Direct expansion models use R410A; chilled water models contain no refrigerant.

Dimensions: Width of 300 mm or 600 mm, 1000 mm depth, 2000 mm height (e.g., ACRC300).

Condenser unit: Air- or water-cooled, optimized for efficiency.

Technical Specifications: Uniflair InRow Cooling ACRC300/ACRC600

Historical Note: The InRow SC (ACSC100) was popular for small data centers but has now been replaced.

files?p_Doc_Ref=SPD_LEAN-9CQLB7_FR_V&p_File_Type=rendition_369_jpg&default_image=DefaultProductImage Enfriamiento para Data Centers: Schneider Electric, APC y Uniflair

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.

Perimeter Cooling Solutions

Application: They cool entire data center rooms. Ideal for medium to large facilities, offering flexible airflow for edge and enterprise environments.

Capacity: From 20 kW to 150 kW, designed for high-density environments.

Refrigerant: Direct expansion with R410A; chilled water without refrigerant.

Dimensions: Vary, e.g., Uniflair AM: 800 mm width, 800 mm depth, 1900 mm height.

Condenser unit: Air- or water-cooled, with remote condensers.

Technical Specifications: Uniflair Room Cooling

Historical Note: The Uniflair LE series was iconic for its reliability, later evolved into the Uniflair AM.

files?p_Doc_Ref=Small_Room_Cooling_Image3&p_File_Type=rendition_369_jpg&default_image=DefaultProductImage Enfriamiento para Data Centers: Schneider Electric, APC y Uniflair

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.

Rack, Ceiling, Wall, or Backpack Solutions

ApplicationCompact solutions for micro data centers or edge computing. Rack units cool individual racks; ceiling and wall units save space in small rooms.

Capacity: From 3.5 kW to 20 kW, for localized cooling needs.

Refrigerant: R410A in direct expansion; chilled water options available.

Dimensions: Rack (e.g., ACRMD4KT-1): 5U height, 19” width; ceiling/wall dimensions vary.

Condenser unit: Split systems, air-cooled or integrated.

Technical Specifications: Uniflair Rack Mounted Cooling

Historical Note: The Uniflair SP Ceiling Mounted Split was key for small IT rooms.

files?p_Doc_Ref=Uniflair_RM_3.5kW_Indoor_FR_H&p_File_Type=rendition_369_jpg&default_image=DefaultProductImage Enfriamiento para Data Centers: Schneider Electric, APC y Uniflair

NOTE: The capacities in this publication are for general reference only. For specific technical details, please contact the Noxtel sales team.

Comparison Tables

InRow Cooling Comparison

ModelApplicationCapacityRefrigerantDimensions (W x D x H)Condenser unit
ACRC300Small to Medium Data Centers5-40 kWChilled Water300x1000x2000mmWater
ACRC600Medium Data Centers10-70 kWChilled Water600x1000x2000mmWater
ACRC100Small Data Centers5-30 kWR410A300x1000x2000mmAir

Perimeter Cooling Comparison

ModelApplicationCapacityRefrigerantDimensions (W x D x H)Condenser unit
Uniflair AMMedium to Large Data Centers20-100 kWR410A / Chilled Water800x800x1900mmAir / Water
Uniflair LELarge Data Centers50-150 kWR410A / Chilled Water1200x900x2000mmAir / Water

Rack/Ceiling/Wall Comparison

ModelApplicationCapacityRefrigerantDimensions (W x D x H)Condenser unit
ACRMD4KT-1Micro Data Centers3.5 kWR410A19”x5UAir
Uniflair SPSmall IT Rooms5-20 kWR410AVariesAir

Table of Equivalences Schneider, APC, Uniflair

BrandProduct LineFocusIconic ModelsCurrent Equivalent
Schneider ElectricUniflair Master RangeComprehensive CoolingUniflair LEUniflair AM
APCInRow CoolingRack CoolingInRow SC (ACSC100)ACRC300/ACRC600
UniflairRoom CoolingPerimeter/Edge CoolingUniflair SPUniflair AM/SP

Conclusion

Schneider Electric, APC, and Uniflair offer specialized cooling for data centers. InRow is ideal for high-density racks, Perimeter units for large rooms, and Rack/Ceiling/Wall units for compact spaces. Choose based on capacity, space, and efficiency. Refer to technical specifications for details.

This is only a general guide to help understand the portfolio; product lines are always changing, so for the most up-to-date information, please consult the official websites.